Gas boilers Buderus 60 kW

Gas boilers Buderus companies have proven themselves in the market with positive side a long time ago. They are produced using German technology, so the quality of the equipment produced remains at a high level. The company produces an extensive the lineup gas units with different characteristics.

Modern Buderus boilers have high efficiency and the ability to operate autonomously. The consumer can choose an option with any power for heating apartments, cottages, warehouses, enterprises, etc.

Consider gas Buderus boiler 60 kW. The Buderus Logano G234X-60 model has this power; it is designed for heating dachas and private houses with an area of ​​up to 560 m². This device is not used in apartments, since it is equipped with an open combustion chamber. This unit has a sectional heat exchanger made of cast iron, which can last about 15 years. It is important that cast iron undergoes corrosion half as much as a steel element.

In one day, cast iron is corroded by a 10% solution of sulfuric acid in the amount of 680 g/m², and in distilled water - 5.51 g/m². For steel these figures are higher. Boilers with a cast iron heat exchanger can be used even at low temperatures. This unit runs on main gas, but if desired, you can also connect liquefied gas from a cylinder, for which you will need to purchase jets.

The boiler control system runs on electricity, so it is necessary to connect it to a 220 V electrical network. To protect the unit from voltage surges and extend its service life, it is recommended to install a stabilizer.

The presence of an open combustion chamber implies a visible flame, air is taken from the room, and smoke is removed through a stationary chimney.

This model of a 60 kW gas boiler is highly economical; most of its analogues consume more fuel under the same operating conditions. The maximum natural gas consumption of this model is 6.4 m3/hour, highest consumption liquefied fuel - 4.5 kg/hour. The boiler efficiency is 93%. The unit has one circuit and works only for heating. It does not provide hot water.

Below is a table of the main characteristics of buderus 60 kW Logano G234X models.

If necessary, the owner of the buderus 60 kW boiler will be able to expand the control system configuration additional functions. Distinctive Features this model are also:

  • possibility of combination with various control systems of the Buderus program Logamatic 2101, Logamatic 2107, Logamatic 4211;
  • design with perfectly matched sections made of high-quality cast iron;
  • combination with adjacent water heater tanks Logalux ST and Logalux SU with a capacity of 150, 200 and 300 l using connecting pipelines;
  • fast and convenient installation;
  • easy conversion to other types of gas;
  • burner design without movable elements;
  • design with a black panel makes it easy to fit the unit into any style of room;
  • low noise.

Buderus Logano G234-60 is designed to operate reliably even at a gas pressure of 10 mbar. This model has the following control system capabilities: operation in weather-dependent mode, Internet connection, control of the recirculation line, solar system, mixing valve, 3-way tap.

How to equip a boiler room for the Buderus Logano G234-60 boiler is described in the video.

Buderus Logamax GB112-60

Another well-known model of a Buderus gas boiler with a power of 60 kW is the Logamax GB112-60. Unlike the previous model, it can be hung on the wall and has more compact dimensions. This model is capable of heating cottages or utility companies with a cascade connection of up to 470 kW.
This boiler model has the ability to smoothly change power from 39% to 100%. The unit has excellent efficiency from 98% to 109%, has a smooth steel heat exchanger made of finned tubes with a large heating area. However, this model does not include an expansion tank. You will have to select it yourself. The condensing boiler can be equipped with a control system and water heater tanks Logalux HC70/110, S120.

In order for the boiler to last as long as possible, it is necessary that the combustion air meets the following requirements:
do not use or store chlorine-containing cleaning products in the room where the boiler is located;
the air should not contain aggressive substances, for example, fluorine and chlorine compounds.
Harmful substances in the air affect corrosion processes.
If in the room where the gas boiler is located, construction works, the following measures should be taken:
turn off and cover the unit;
Before starting up the device, do not forget to clean the dusty burner.
Water quality also plays a significant role in extending the life of the unit, as well as increasing the efficiency, reliability and performance of the heating system. If the level of calcium in the water used is high, lime deposits appear on the surface of the heat exchanger, preventing the water from heating. As a result, the temperature of the heat exchanger increases and thermal loads appear.
If the water is too hard, you need to install a filter device at the inlet.


To obtain the required temperature in the room, the thermostatic valves must be fully opened. If optimal level heat is not reached for a long time, set the temperature on the regulator even higher.

Note! If you frequently add water to the heating system, it will fail faster due to corrosion and scale formation.

If the gas boiler is temporarily not in use, the coolant is drained from the system.
Boiler maintenance and cleaning must be carried out once a year. In this case, it is necessary to check the functionality of the entire system. Maintenance, installation, gas and power connections, and the first start-up of the Buderus 60 kW unit must be performed only by a specialist from a specialized enterprise that has permission to carry out such work.

Exhaust gas monitoring device

The boiler can be equipped with an exhaust gas monitoring system, for example, when operating the unit in a roof boiler room. This device turns off the gas supply if the fuel goes into the room where the unit is installed, as a result of which the burner turns off. After 15 minutes it turns on again. If the device operates too often, it means there is a malfunction in the chimney pipe. Then you should call a specialist.

What to do if the burner malfunctions?

If any malfunction occurs in the operation of the burner, the signal button for suppressing boiler interference lights up. In this case, system faults are displayed on the display. To continue operating the unit, press the burner suppression button and try to light it again. If the burner does not turn on after several attempts, call a specialist.

Note! You can press the noise suppression button no more than three times. If you do this more often, you can cause damage to the burner ignition transformer.

When operating Buderus gas boilers with a power of 60 kW, they should be located in the basement, attic or in specially equipped boiler rooms. Such units are not equipped with a circuit for supplying hot water, but you can always purchase additional components and use them to obtain a system that meets your needs.

Buderus Logano G234-60 G20 60kW, atmospheric burner, single-circuit

Logano G234

  • Boiler block design with perfectly matched sections
  • Boiler sections made of high quality cast iron GL 180 M
  • Combustion chamber closed on all sides
  • Intensive heat transfer of heating surfaces thanks to special fins
  • Easy to install and Maintenance, thanks to its simple design
  • Fully automatic operation with electric ignition, no additional gas consumption required for ignition
  • To make it easy to connect gas to the boiler at the back, there is a gas pipeline under its casing.
  • 80 mm thick thermal insulation reduces heat loss to a minimum
  • The heating boiler is completely assembled together with the casing - this saves time and installation costs
  • Compact dimensions - an advantage when carried through openings and when placed in a boiler room
  • Various combinations with control systems and cylinders - to suit every need
  • Large selection of additional equipment for quick installation, adapted to a specific boiler
Low emission gas burner with premix
  • Fully automatic burner with electric ignition
  • Ionization flame control and double magnetic valve
  • New system combustion reduces emissions harmful substances
  • The Venturi tube of a gas burner ensures almost 100% mixing of fuel with air. During the combustion process, many small individual flames are formed without a high-temperature core. Therefore, in such gas burners the combustion temperature is significantly reduced. In addition, the short flame of these fireplaces easily breaks away from the burner rod, reducing the heat load on it
Supply
  • Heating boiler - for operation on natural gas E (G 20), with thermal insulation and boiler casing - 1 box
  • Parts for conversion to liquefied gas P (G31) (optional) - 1 box
  • Control system (optional) - 1 box
Design Guidelines

Hydraulic resistance of the boiler through water

Fuel

The gas burners have been factory adjusted, comparable to the EE-H method, to natural gas E (G20). You can change the gas type to liquefied P (G31) at any time using the conversion parts (optional). Conversion to city gas is not possible. The supplied gas pressure (supplied pressure is the static excess pressure of the gas relative to atmospheric pressure when it flows out at the connection point of the gas appliance) must be in the following range:

The maximum supply pressure when operating on natural gas can be 25 mbar. If the supplied gas pressure is higher, it is necessary to install an additional gas pressure regulator on the burner. The maximum test pressure is 150 mbar.

Flue gas temperature / chimney connection

The required pressure is for all boiler sizes a minimum of 3 and a maximum of 10 Pa.
For more precise adjustment and maintenance of draft in the chimney, as well as for organizing ventilation of the chimney itself, it is recommended - after consultation with an authorized chimney specialist - to install and adjust an additional air regulator (draft limiter). The cross-section of the auxiliary air regulator depends on the effective height and cross section chimney.

Flue gas shut-off valve

If desired, a flue gas shut-off valve can be purchased as an additional order. A flue gas shut-off valve installed before the draft breaker is more effective than one installed after it.

Installations with underfloor heating

In floor heating systems using oxygen-permeable plastic pipes (DIN 4726), it is necessary to install a heat exchanger between the boiler and the floor heating system.

Preparing hot water

The heating boiler can work with any water heater tank. Combinations of the boiler with tanks of the Logalux ST/SU series have particular advantages.

General provisions

  • For heating boilers that must be equipped with a flue gas monitoring system according to the FeuVO of the relevant federal state, accessories can be supplied
  • For version B11 (without flue gas monitoring system), the boiler may only be installed in rooms that have the required ventilation to the atmosphere and also have a self-closing and sealed door, for example in boiler rooms
  • For version B11 BS (with flue gas monitoring system), the heating boiler can be installed in apartments or similar places
  • To ensure the functioning of the boiler, all connections must be made in the places specified for them
  • When installing a gas heating boiler operating on liquefied gas below ground level, it is recommended to install a second solenoid valve. A switchgear for controlling the solenoid valve can be supplied as an option
  • In installations with underfloor heating, with several heating circuits, as well as in installations with large water volumes, provisions must be made, based on local operating conditions, installation of a mixer for regulating heating circuits.
Inspections

To ensure environmentally friendly and trouble-free operation and in accordance with § 10 EnEV, regular inspections of the boiler and burner are recommended.

Boiler installation room

When installing the boiler, the minimum distances shown (shown in parentheses) must be observed. For ease of installation, servicing and maintenance, it is necessary to maintain the recommended distances from the walls.

The room for installing equipment must be protected from the cold and have good ventilation. In addition, care must be taken to ensure that the combustion air is not contaminated with dust or halogenated hydrocarbons. Halogenated hydrocarbons of all types are found, for example, in aerosol cans, solvents and cleaners, varnishes, paints and adhesives.

Modern universal boiler concept

  • Low temperature heating boiler according to DIN EN 297 with continuously variable boiler water temperature control without base temperature (minimum boiler water temperature)
  • Options for operation with natural gas E or liquefied gas P
  • Boiler design with perfectly fitted sections made of high quality cast iron
  • Tested and reliable heating boiler with cast iron heat exchanger and atmospheric gas burner
  • Combines with adjacent Logalux ST and Logalux SU water heater tanks from the Buderus program
  • Can be combined with various control systems from the Buderus program
  • High standardized utilization rate (93%) and low emissions of harmful substances
Operation with reduced noise levels and low emissions
  • Atmospheric gas burner with pre-mixing without fan
  • Heating mode without additional noise reduction measures
  • Harmful emissions are below the Blue Angel environmental requirements
  • CE mark
Simple and convenient control
  • Control functions coordinated with the plant hydraulics
  • Easy setup of all control system functions (Push and Turn principle)
  • It is possible to expand the configuration of all control systems for additional modules
Fast installation, commissioning and maintenance
  • A system for quickly installing the heating circuit, adapted to the corresponding hydraulic circuit, for connection to the boiler or wall mounting
  • Convenient connection of Logalux ST and Logalux SU water heater tanks with a capacity of 150, 160, 200 and 300 liters to the boiler thanks to the boiler-water heater connecting pipeline with loading pump and check valve
  • Burner design without moving parts
  • Easy conversion of the burner to other types of gas

Buderus Logano G234 60 kW- heating boiler equipped with an atmospheric gas burner with pre-mixing. It is an ideal choice for heating large buildings. With its help, you can very economically organize the supply of heat in situations where more power is required. In combination with a cylinder water heater, it is easy to implement a comfortable hot water supply system.

The principle of atmospheric combustion is as follows: gas is automatically supplied to the burner along with the atmospheric air necessary for combustion. In this case, you do not need to use an electric fan, as in other heating boilers. Since the fuel is burned in separate flames, the flame does not come into contact with the burner tube, it does not heat up and will therefore last longer.

Buderus Logano G234 60 kW - hydraulic circuits using boiler combinations with various burners and control systems:

  1. Logamatic 2107: single-stage burner – water heater tank – circulation pump. Complete with FM 241: heating circuit with mixer. Complete set with FM 242: 2 two-stage or modulating burner. Complete set with FM 244: solar collector.
  2. Logamatic 4211: single, two-stage or modulating burner - water heater tank - circulation pump. Complete with FM 442: two heating circuits with mixer. Complete with FM 445: system with external heat exchanger. Complete with FM 443: solar collector module. Complete set with FM 446: EIB interface single electronic system home management. Equipped with FM 448: general fault message.
  3. Logamatic 2101 (operation mode with constant boiler water temperature): single-stage burner.

Buderus Logano G234 60 kW - advantages of a low-temperature gas boiler:

  • Ionization flame control and double magnetic valve;
  • Low level of emissions of harmful substances;
  • Low noise operation;
  • Compact dimensions and the ability to install the water heater to the right or left of the boiler;
  • High efficiency (up to 93%), thanks to the intense heat transfer of the heating surfaces of the cast iron heat exchanger;
  • Simplicity of installation and service;
  • Reliability and durability of the boiler design made of gray cast iron;
  • Ease of combining and selecting control systems and water heater tanks from the Buderus program;
  • Highly effective thermal insulation;
  • There are no restrictions on the minimum boiler water temperature.

Buderus Logano G234 60 kW - boiler purpose:

Can be used to heat buildings up to 600 m2, satisfying average heat needs. With additional equipment, the boiler can be connected to the DHW circuit.

Heating devices with a power of 60 kW are ideal for heating a country cottage, commercial or industrial property. It can run on natural and liquefied gas, so it is suitable for any facility, including those without a central gas supply.

Specifications

  • Rated thermal power (kW): 60;
  • Dimensions HxWxD (mm): 1204x830x726;
  • Boiler water volume (l): 31;
  • Without control system;
  • Weight (kg): 310;
  • Permissible excess operating pressure (bar): 4;
Delivery of goods in Moscow and the Moscow region is carried out by our own trucks within a pre-agreed timeframe and depends on the weight and category of your product.

Please check with the manager for the cost of delivery of goods weighing more than 1500 kg.

* Free shipping products of the "Light" category are carried out when ordering from 1000 rubles.

We deliver orders from Monday to Saturday from 10:00 to 18:00. On the day of delivery, the driver will contact you 1.5 hours before arrival. If delivery at other times is convenient for you, please check the conditions with the manager. Delivery after 18:00 is charged separately. Each additional hour after 18:00 + 400 rubles to the delivery cost.

Pickup of goods is available by prior arrangement, after confirmation of receipt of the order at the pickup warehouse.

Please note that upon receipt of the goods legal entities a power of attorney is required for individuals– identification document.

DELIVERY TO THE REGIONS OF RUSSIA

Delivery to regions of Russia (except for Moscow and the Moscow region):

Delivery of orders to the regions is carried out through transport companies. We deliver and ship your order to the carrier. You can independently calculate the cost of delivering an order to your region; for this, almost every transport company has an online calculator on its official website. You need to enter certain values ​​(weight and volume, number of seats), departure points and destinations!

Upon receipt of your order, you will need to pay the cost transport services. The cost of delivery to the transport company's warehouse is calculated according to local delivery rates.

Below are the websites of the most popular and reliable transport companies:

# Transport companies
1 Business Line
2 PEC
3 ZhelDorExpedition
4 ZheldorAlliance
5 BaikalService
6 WHALE

Delivery can also be made to any other transport company according to your choice.

If for some reason you want us to send your order to another transport company, just tell us its coordinates, and we will send the goods as quickly as possible.

Delivery to the regions of the Russian Federation is made only after full prepayment of the cost of the purchased goods (receipt Money to the store's bank account).

The floor-standing gas cast-iron heating boiler “Buderus Logano G234X (WS) 60-7” with a power of 60 kW with an atmospheric burner appeared in an updated version in 2017 - with modern standard automation EMS Plus and spectacular industrial design from Buderus. This new generation boiler has retained the basic qualities of its predecessor, such as high performance at low costs, reliability, efficiency, and compactness. Works on both natural and liquefied gas. The boiler is designed for heating large buildings, since it can be used to organize economical heating when high power is required. In combination with high-quality floor-standing water heaters "Buderus" of the "Logalux ST" and "Logalux SU" series, it allows you to implement a comfortable hot water supply system.

The atmospheric gas burner with pre-mixing, which the boiler is equipped with at the factory, does not have a fan, which ensures silent operation. There is no need for additional noise reduction measures during heating mode. The burner operates fully automatically, ignition is electric and does not require additional gas consumption.

The low-temperature heating boiler “Logano G234X (WS) 60-7” is equipped with an efficient heat exchanger with 7 sections, made of high-quality gray cast iron GL 180 M. The sections are ideally matched to the design of the boiler block and have special fins, due to which there is intense heat transfer from the heating surfaces. The boiler is equipped with 80 mm thick thermal insulation, which, together with the cladding, prevents energy loss.

The new boiler model “Logano G234X (WS)” is designed specifically for installation modern system control "Buderus Logamatic MC110" standard EMS Plus. This automation is optionally equipped with a “RC 310” or “BC 30 E” controller with a touch screen and full-text menu. Such a system allows you to work in a weather-dependent mode, controls the boiler and indirect heating boiler, recirculation line, 3-way valve, and also informs about the current status, selected functions, and errors. Control is carried out using a 0-10 V signal. Setting up all options is intuitive and very simple - according to the “Push and turn” principle. All control functions are coordinated with the installation hydraulics. The control system can be expanded with additional modules: mixing modules, Internet connection module, cascade module with the ability to control up to 4 boilers, modules for solar systems. For complex systems, it is recommended to use the new generation of professional automation “Logamatic 5000”. The control system is not included in the boiler delivery and must be ordered separately.

The “Logano G234X (WS)” boiler is delivered fully assembled, with casing and gas burner, which allows you to significantly save installation time and costs and allow quick commissioning. The quick installation system for the heating circuit for connection to the boiler or wall mounting is adapted to the corresponding hydraulic circuit. The water heater tank is conveniently connected to the boiler using a connecting pipeline with a loading pump and a check valve. The burner design has no moving parts, and its conversion to other types of gas is as simple as possible. Since the combustion process occurs with virtually no soot formation, maintenance and cleaning work is reduced to a minimum. This heating boiler is pre-set for natural gas. For conversion to liquefied gas, a special conversion kit is used (optional).

Main features and advantages of the Logano G234X (WS) 60-7 boiler:

  • Nominal heating output (at 80/60 °C): 60 kW
  • Heat exchanger made of special gray cast iron
  • 7 cast iron sections that are perfectly matched to each other
  • Intensive heat transfer of heating surfaces thanks to special fins
  • High standardized efficiency at maximum power (at 80/60 °C): 92.2%
  • Options for operation on natural or liquefied gas
  • Fully automatic atmospheric burner with electric ignition
  • Burner control SAFe
  • Ionization flame control and double magnetic valve
  • Low emissions of harmful substances
  • Quiet and reliable operation
  • Combustion chamber closed on all sides
  • The presence of a gas pipeline under the boiler casing for ease of gas connection from the rear
  • Richer functionality due to combinations with control systems EMS And EMS Plus from the program "Buderus" (optional equipment)
  • Simple and convenient control
  • Low-temperature, economical operating mode to reduce heating costs
  • Smooth control of boiler water temperature without basement temperature
  • Possibility of combination with a number of installed boilers “Logalux ST” and “Logalux SU”
  • 80 mm thick thermal insulation, reducing heat loss to a minimum
  • Quick installation - the boiler is already completely assembled along with the casing
  • Compact dimensions - convenient to carry through openings and place in the boiler room
  • Easy installation and maintenance thanks to simple design
  • Case of a new original “industrial” design in black and blue design
  • Modern technology High Quality
  • Large selection of additional equipment adapted to the boiler for quick installation